APC Galaxy 300 10kVA 400V 3:1 with Long Backup Charger(M), Start-up 5×8

G3HT10K3ILMS

Galaxy 300 10kVA 400V 3:1 with Long Backup Charger(M), Start-up 5x8

Category:

Output

Output power capacity
8.0kWatts / 10.0kVA
Max Configurable Power (Watts)
8.0kWatts / 10.0kVA
Nominal Output Voltage
230V
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion
Less than 3%
Output Frequency (sync to mains)
50/60 Hz +/- 5%
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Other Output Voltages
220, 240
Load Crest Factor
2.5 : 1
Topology
Double Conversion Online
Waveform type
Sine wave
Overload Operation
60 seconds @ 120% and 30 seconds @ 145%
Maximum Output Current
65
Output Connections
(1) Hard Wire 3-wire (H N + G) (Battery Backup)
Output Voltage THD
< 3% linear load and <5% non-linear load
Output Voltage Tolerance
+/- 2% static and 100% load step
Bypass
Built-in Maintenance Bypass

Input

Nominal Input Voltage
400V 3PH
Input frequency
45 - 65 Hz
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations
340 - 477V
Input Total Harmonic Distortion
Less than 5% for full load
Type of Input Protection Required
gL fuse
Other Input Voltages
380, 415
Maximum Input Current
19.0A
Input Power Factor at Full Load
0.94

Batteries & Runtime

Battery type
No internal battery - uses external battery system
Typical recharge time
24hour(s)

Communications & Management

Pre-Installed SmartSlot™ Cards
Control panel
Multi-function LCD status and control console
Emergency Power Off (EPO)
Yes

Physical

Maximum Height
1300MM, 130.0CM
Maximum Width
400MM, 40.0CM
Maximum Depth
950MM, 95.0CM
Net Weight
145.0KG
Shipping weight
170.0KG
Shipping Height
1440MM, 144.0CM
Shipping Width
800MM, 80.0CM
Shipping Depth
965MM, 96.5CM

Environmental

Operating Temperature
0 - 35 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0-3000meters
Storage Temperature
-10 - 60 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0-9000meters
Audible noise at 1 meter from surface of unit
54.5dBA
Online thermal dissipation
707.0BTU/hr
Protection Class
IP 20

Conformance

Approvals
CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-2, TUV, VFI-SS-111
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

RoHS
Compliant
Battery Directive
Compliant

Reviews

There are no reviews yet.

Be the first to review “APC Galaxy 300 10kVA 400V 3:1 with Long Backup Charger(M), Start-up 5×8”

Your email address will not be published. Required fields are marked *